Petroleum Dry Cleaners - Subpart JJJ
NSPS Notebook
Petroleum Dry Cleaners - Subpart JJJ
Applicability
eCFR Subpart JJJ [ecfr.gov]
This subpart applies to:
- Affected facilities located at petroleum dry cleaning plants with a total manufacturers' rated dryer capacity of at least 38 Kg (84 lbs), which commence construction or modification after Dec 14, 1982*.
Affected facilities:
- Petroleum solvent dry cleaning dryers;
- Washers;
- Filters;
- Stills;
- Settling tanks.
Total dryer capacity includes all of the dryers that use petroleum solvent at the dry cleaning plant. If the plant has both petroleum and perchloroethylene dryers, only the petroleum dryers are included in the total capacity.
Perchloroethylene dry cleaning machines are regulated under NESHAP M.
Not subject to this subpart:
- Dryers installed between December 14, 1982 and September 21, 1984, in a plant with an annual solvent consumption level of less than 4,700 gallons.
Date of Original Final Rule
Amendments Dates
10/17/2000 (65 FR 61744)
11/27/1985 (50 FR 49026)
State Regulations
Title 129, Chapter 12, Section 001.62
Previously: Chapter 18, Section 001.35
Federal Regulations
40 CFR 60.620
Related Rules
NESHAP - 40 CFR Part 63
Subpart M - Perchloroethylene dry cleaning
Regulations and Federal Registers
eCFR Subpart JJJ [ecfr.gov]
FAQ's, Fact Sheets, and Rules Summaries
TCEQ Flowchart [tceq.state.tx.us]